Leave Your Message

Products

1000VDC T2 Surge Protective Device wi...1000VDC T2 Surge Protective Device wi...
01

1000VDC T2 Surge Protective Device wi...

2025-09-24

This advanced twopole surge protective device is engineered for 1000VDC electrical systems, providing reliable protection against transient overvoltages and lightning strikes. The unit features a distinctive grey background with orange accents on its 2P configuration, creating high visual contrast for easy identification in electrical enclosures. With a maximum discharge capacity of 40kA and T2 classification, the device ensures robust surge protection for critical applications. The plastic housing offers excellent electrical insulation and mechanical durability, meeting international safety standards for surge protective devices.

view detail
4P 275V T2 Surge Protective Device 20...4P 275V T2 Surge Protective Device 20...
02

4P 275V T2 Surge Protective Device 20...

2025-09-24

This four-pole Type 2 surge protective device offers complete protection for three-phase electrical systems with neutral conductor. Designed for 400V AC systems with maximum continuous operating voltage of 275V per phase, the device provides comprehensive protection against lightning-induced surges and switching transients. Compatible with both 50Hz and 60Hz power networks, it ensures reliable performance in various industrial and commercial applications with its 20kA nominal discharge capacity.

view detail
3P 275V T2 Lightning Arrester 20KA to...3P 275V T2 Lightning Arrester 20KA to...
03

3P 275V T2 Lightning Arrester 20KA to...

2025-09-24

This three-pole Type 2 surge protective device is designed for reliable overvoltage protection in three-phase electrical systems. With a maximum continuous operating voltage of 275V and compatibility with 50/60Hz power networks, the device provides comprehensive protection against lightning-induced surges and switching transients. The 20kA nominal discharge capacity ensures stable performance in various industrial and commercial applications.

view detail
2P 275V T2 20KA-40KA Lightning Surge ...2P 275V T2 20KA-40KA Lightning Surge ...
04

2P 275V T2 20KA-40KA Lightning Surge ...

2025-09-24

This two-pole Type 2 surge protective device provides reliable overvoltage protection for 230V/240V AC electrical systems. With a maximum continuous operating voltage of 275V and compatibility with both 50Hz and 60Hz power networks, the device offers effective protection against lightning-induced surges and switching transients. The 20kA nominal discharge capacity ensures stable performance in various commercial and industrial applications.

view detail
1P 275V T2 Lightning Arrester 20KA to...1P 275V T2 Lightning Arrester 20KA to...
05

1P 275V T2 Lightning Arrester 20KA to...

2025-09-24

The 1P 275V T2 Surge Protective Device (SPD) represents advanced protection technology designed to safeguard electrical installations against transient overvoltages and lightning-induced surges. Operating at 275V with 50/60Hz frequency compatibility, this single-pole device provides critical protection for residential and commercial electrical systems. With a surge current handling capacity ranging from 20KA to 40KA, this SPD effectively mitigates the damaging effects of electrical surges, ensuring equipment safety and system reliability.

view detail
Self-Resetting Overvoltage and Underv...Self-Resetting Overvoltage and Underv...
06

Self-Resetting Overvoltage and Underv...

2025-08-21

Introduction to the overvoltage and undervoltage delay protector for three-phase 4P63A incoming line:

Functional features
Overvoltage and undervoltage protection: When overvoltage or undervoltage occurs in a three-phase line, it can quickly cut off the circuit to protect the equipment at the back end. The overvoltage action value is 460V±5V, and the undervoltage action value is 300V±5V.
Automatic reset: Once the voltage returns to the normal range, the protector will automatically reconnect the circuit after the specified delay time. The recovery delay time is 60 seconds.
Other protections: Some products also feature protection functions such as phase failure, neutral line failure, and three-phase imbalance. The 3P+N system can monitor and protect against various fault conditions.

view detail
The Solar Fuse Uses a Photovoltaic DC...The Solar Fuse Uses a Photovoltaic DC...
07

The Solar Fuse Uses a Photovoltaic DC...

2025-08-21

This series of fuses is suitable for circuits with rated DC voltage up to 1000Vand rated current up to 30A They are connected in series and parallel withphotovoltaic panels and batteries to provide short-circuit breaking protection forcharging and converting systems; Simultaneously, for photovoltaic power plants,combiner inverter rectification systems, and short-circuit fault breaking protectionAnd for the rapid breaking protection of surge current and short-circuit faultovervoltage in photovoltaic power generation systems, with a rated breaking capacityof 20KA. 0ur company is currently conducting relevant tests to further improve thebreaking capacity of the product. The product complies with the provisions of theInternational Electrotechnical Commission standard EC60269.

view detail
Micro Contactor Rail-Mounted 2P63A4 N...Micro Contactor Rail-Mounted 2P63A4 N...
08

Micro Contactor Rail-Mounted 2P63A4 N...

2025-08-21

The SRH8 series household AC contactors (hereinafter referred to as contactors) are mainly applicable to circuits with an AC frequency of 50Hz(or 60Hz), a rated working voltage up to 400V, and a rated working current up to 63A, for controlling household appliances and similar low-inductance and micro-inductance loads. They can also be used to control household electric loads, in which case the control electric power should be reduced accordingly. The product is used in homes, hotels, apartments and other places to achieve automation functions and is applied in large-scale production of household appliances.

view detail
Dual Power Manual Transfer Disconnect...Dual Power Manual Transfer Disconnect...
09

Dual Power Manual Transfer Disconnect...

2025-08-21

The SR219G-125 disconnector (hereinafter referred to as the switch) is suitable for AC 50/60Hz, rated current 125A and below, and rated voltage up to 400V in distribution and control circuits. It is mainly used as the main switch in terminal combined electrical apparatus and can also be used for infrequent control of various low-power electrical appliances and lighting. It is widely used in industrial and mining enterprises, high-rise buildings, commercial and other fields Places such as families.

view detail
L7 Photovoltaic DC Miniature Circuit ...L7 Photovoltaic DC Miniature Circuit ...
10

L7 Photovoltaic DC Miniature Circuit ...

2025-08-14

Definition: The L7 photovoltaic DC circuit breaker is a miniature circuit breaker suitable for circuits with an AC frequency of 50Hz/60Hz, a rated working voltage of DC500V, DC1000V, or DC1500V, and a rated current up to 63A.
Application: It is mainly used in industrial, commercial, high-rise, and residential buildings, serving as a means for infrequent connection, disconnection, and switching of distribution lines, providing overload and short-circuit protection for lines and equipment. 
Installation method: Usually installed on TH35-7.5 mounting rail, with installation category being II and III.

Main Parameters 
Rated current: There are multiple options available, including 1A, 2A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, and 63A.
Rated short-circuit breaking capacity: Generally, there are two options: 6kA and 10kA.
Pole number: It includes single-pole, two-pole, three-pole, and four-pole. The rated voltage of single-pole circuit breakers is 230V, while that of two-pole, three-pole, and four-pole circuit breakers is 400V.
Instantaneous tripping current form: There are three types: B, C, and D.

view detail
Photovoltaic DC Miniature Circuit Bre...Photovoltaic DC Miniature Circuit Bre...
11

Photovoltaic DC Miniature Circuit Bre...

2025-08-14

PV DC circuit breakers are primarily used for on/off control and fault protection of DC circuits in PV systems. Common application scenarios include:
1. PV Module Side
Within the PV array's combiner box, they protect the DC circuits of individual PV modules or strings, preventing module failures (such as short circuits or overloads) from affecting the entire array.

2. Inverter FrontEnd
In the DC side of the circuit connecting the PV array and the inverter, they quickly disconnect the DC power supply when the inverter fails or requires maintenance, ensuring the safety of equipment and personnel.

3. Energy Storage System Interface
In a combined PV and energy storage system, they control the circuit between the PV DC side and the energy storage battery, preventing energy storage system failures from adversely affecting the PV array.

4. DC Merging Link
In the DC merge cabinet of a large PV power plant, they protect the circuit after multiple PV strings merge, ensuring stable and safe current flow during the merging process.
These scenarios all need to deal with the high voltage and high current characteristics of photovoltaic DC circuits, and avoid safety hazards such as arcing. Therefore, there are special requirements for the arc extinguishing ability and highvoltage resistance of the circuit breaker.

view detail